1. <th id="jxi7s"><em id="jxi7s"></em></th>
        <del id="jxi7s"><dl id="jxi7s"></dl></del>
        <em id="jxi7s"></em>
          <th id="jxi7s"><progress id="jxi7s"></progress></th>
          <b id="jxi7s"><menuitem id="jxi7s"></menuitem></b>

            <del id="jxi7s"><form id="jxi7s"></form></del>

            1. X

              Leave Message

              E-Mail: [email protected]

              Tel: 13567723322

              English
              Contact Us

              Position: Index>News > Installation requirements for electro-hydraulic slurry valve

              2024-01-02

              Installation requirements for electro-hydraulic slurry valve

              Electro hydraulic slurry valveIt has a wide range of applications, especially in industries such as water conservancy, electricity, chemical engineering, metallurgy, etc. It has the characteristics of compact structure, easy operation, good sealing performance, and long service life. The ability of the electro-hydraulic slurry valve to exhibit these characteristics and performance is closely related to its correct installation. This article will introduce the installation requirements of the electro-hydraulic slurry valve.

              液動(dòng)漿液閥

              Installation requirements for electro-hydraulic slurry valve:

              1、 Environmental requirements

              Firstly, the environment for installing the electro-hydraulic slurry valve should be kept dry and ventilated, and the valve should be kept away from high temperature sources and corrosive gases to prevent damage and aging of the valve.

              2、 Pre installation inspection

              Before installation, it is necessary to check whether the model and specifications of the valve meet the design requirements, whether the various components of the valve are intact, whether the sealing surface of the valve is flat, and whether the operating mechanism of the valve is flexible and reliable.

              3、 Installation direction

              The installation direction of the electro-hydraulic slurry valve should be determined according to the fluid flow direction. Normally, the inlet of the valve should face the direction of fluid flow.

              電動(dòng)漿液閥Z73X

              4、 Interface connection

              The interface of the valve should be tightly connected to the pipeline, and there should be no air or liquid leakage. When connecting, excessive force should be avoided as much as possible to avoid damaging the valve.

              5、 Power connection

              The power supply of the electro-hydraulic slurry valve should be connected to the designated power supply, and the voltage and frequency of the power supply should meet the requirements of the valve. When connecting the power supply, attention should be paid to the wiring sequence of the valve, as incorrect wiring may cause the valve to malfunction.

              6、 Trial operation

              After installation, a trial run should be conducted to check whether the valve opens and closes normally, whether there is any air or liquid leakage, and whether the valve operates flexibly.


              Prev 2023-12-25

              Introduction to the working principle of electro-hydraulic plug-in valve

              Next 2025-12-10

              Analysis of installation and maintenance points of slurry valve in working conditions on site

              05

              2022.01

              What are the types of ceramic materials for ceramic valves?

              The emergence of new materials allows the valve to have more choices in the selection of raw materials, and the diversification of materials...

              05

              2022.01

              Characteristics and applications of ceramic valves

              Ceramic valves mainly include ceramic gate valves, ceramic ball valves, etc. This type of valve is called the nemesis of strong corrosion an...

              17

              2024.05

              Reasons and elimination methods for knife gate valve failure

              Possible faults, causes, and elimination methods of knife gate valves:Possible faults that may occurReason for malfunctionElimination method...

              Contact Us

              wechat

              Wechat

              Hotline

              135-6772-3322

              Tel: 0577-67962833

              Sales: 0577-67371666

              Address: Wuxing Industrial Zone, Oubei Town, Yongjia County, Wenzhou City, Zhejiang Province, China

              E-mail: [email protected]

              Copyright? 2025 Zhejiang Yongguan Valve Co., Ltd. All Rights Reserverd

              浙ICP備11044792號(hào)

              1. <th id="jxi7s"><em id="jxi7s"></em></th>
                  <del id="jxi7s"><dl id="jxi7s"></dl></del>
                  <em id="jxi7s"></em>
                    <th id="jxi7s"><progress id="jxi7s"></progress></th>
                    <b id="jxi7s"><menuitem id="jxi7s"></menuitem></b>

                      <del id="jxi7s"><form id="jxi7s"></form></del>

                      1. 69视频免费在线 | 亚洲视频中文字幕在线播放 | 男人爱天堂资源网 | 成人性毛片 | 99久久免费看 |